弯管下游在线校准超声流量计安装位置研究
DOI:
CSTR:
作者:
作者单位:

1. 苏州市计量测试院 苏州 215128;2. 中国计量大学计量测试工程学院 杭州 310018

作者简介:

通讯作者:

中图分类号:

TH814

基金项目:

国家自然科学基金青年项目(12002335)、浙江省自然科学基金探索项目(LQ20E060006)资助


Research on the install position of on-line calibration ultrasonic flowmeter downstream of an elbow
Author:
Affiliation:

1. Suzhou Institute of Metrology, Suzhou 215128, China; 2. College of Metrology and Measurement Engineering, China Jiliang University, Hangzhou 310018, China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为减少现场扰流元件对超声流量计在线校准的干扰,采用大涡模拟方法研究超声流量计上游存在90弯头时其沿流向和周向安装位置对计量准确性的影响,获得超声流量计的最佳安装位置。结果表明,弯头导致下游发生流态畸变,超声流量计距弯头越远,其对周向安装位置的敏感度越低,修正系数最大误差由0.11降至0.03;修正系数随周向安装角的变化而波动,且管内流速越高,修正系数波动幅值越小,波动幅值最大减少了20.5%。此外,周向安装角为0和180时流量计对安装位置的敏感度较低,修正系数更接近于1.0且其最大误差均在0.04以内。研究结果有助于提高弯头扰流条件下超声流量计在线校准的准确性。

    Abstract:

    In order to reduce the interference of the on-line calibration of the ultrasonic flowmeter by the on-site spoiler, the large eddy simulation method is used to study the influence of the installation position along the flow direction and circumferential direction on the measurement accuracy when there is a 90° elbow upstream of the ultrasonic flowmeter, so as to obtain the best installation position of the ultrasonic flowmeter. The results show that the elbow causes the downstream flow pattern distortion. The farther the ultrasonic flowmeter is from the elbow, the lower its sensitivity to the circumferential installation angle, and the maximum error of the correction coefficient decreases from 0.11 to 0.03; the correction coefficient fluctuates with the change of the circumferential installation angle, and the higher the flow velocity in the pipe, the smaller the amplitude of the correction coefficient fluctuation, and the maximum fluctuation amplitude is reduced by 20.5%. In addition, when the circumferential installation angle is 0° and 180°, the sensitivity of the flowmeter to the installation position is lower, the correction coefficient is closer to 1.0, and the maximum error is within 0.04. The results are beneficial to improve the on-line calibration accuracy of the ultrasonic flowmeter under complicated flow conditions caused by the on-site spoiler.

    参考文献
    相似文献
    引证文献
引用本文

张东飞,耿存杰,李国占,张洪军.弯管下游在线校准超声流量计安装位置研究[J].电子测量技术,2021,44(23):6-11

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2024-07-02
  • 出版日期:
文章二维码
×
《电子测量技术》
财务封账不开票通知