基于改进阈值函数法在声波法直埋供热管网泄漏检测中应用
DOI:
CSTR:
作者:
作者单位:

1.北京建筑大学环境与能源工程学院 北京 100044; 2.北京市热力集团有限公司 北京 100028

作者简介:

通讯作者:

中图分类号:

TU995.3

基金项目:

北京市热力集团合作项目(KY191007)、北京学者计划项目(2015NO.022)、北京市教育委员会科研计划项目(KM202310016006)资助


Research on the leak detection of directly buried heating pipe network by an improved threshold function
Author:
Affiliation:

1.School of Environment and Energy Engineering, Beijing University of Civil Engineering and Architecture,Beijing 100044, China; 2.Beijing Thermal Group Co.,Ltd.,Beijing 100028,China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为提高声波法直埋热水供热管网泄漏应用的定位精度,在分析各种小波法阈值函数适用性的基础上,提出了改进阈值函数降噪方法,该方法理论上能够克服软阈值函数的恒定偏差和硬阈值函数信号振荡的缺点,设置调节参数,提升降噪能力,保留小于阈值点区域信号,避免有效信号丢失。在大型直埋热水循环管网中进行泄漏测试实验,研究表明采用本方法进行声波法直埋供热管道泄漏检测,可实现泄漏定位误差在±1 m内,定位精度可达0.11%~3.49%,最后选择北京市供热系统中实际工程案例,采用本方法进行声波法泄漏检测,泄漏定位误差为0.37%~0.66%,定位精度提升。

    Abstract:

    To improve the positioning accuracy of the leakage application of the direct buried hot water heating pipe network by acoustic method, based on the analysis of the applicability of various wavelet threshold functions, an improved threshold function noise reduction method is proposed. This method can theoretically overcome the constant deviation of the soft threshold function and the shortcomings of the hard threshold function signal oscillation. Through setting adjustment parameters, improving the noise reduction ability, and retaining the signal of the region less than the threshold point to avoid effective signal loss. The experiment was carried out in a large direct buried hot water circulation pipe network. The research showed that the leakage positioning error was within ±1 m and the positioning accuracy reached 0.11%~3.49%. Finally, the acoustic leakage detection method was adopted in a practical engineering case of a Beijing heating system. The leakage location error is 0.37%~0.66%, and the positioning accuracy has efficiently is improved.

    参考文献
    相似文献
    引证文献
引用本文

徐自强,李成,穆连波,王随林,刘建军.基于改进阈值函数法在声波法直埋供热管网泄漏检测中应用[J].电子测量技术,2024,47(6):143-150

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2024-06-07
  • 出版日期:
文章二维码
×
《电子测量技术》