1. Henan STAR Electric Power Equipment Co., Ltd., Xuchang,461500, China; 2. School of Electrical Engineering, Xi'an Jiaotong University, Xi'an,710049, China; 3. State Grid Shaanxi Electric Power Company Electric Power Research Institute, Xi’an 710048, China; 4. China Electric Power Research Institute, Wuhan 430074, China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    针对石墨基柔性接地材料在配电系统接地中的应用问题,构建了有限元仿真模型对一组10kV配电网石墨基柔性接地装置的接地电阻进行计算,并结合石墨基柔性接地材料的固有特性和常用降阻方式,结果发现在城市配电网应优先采用矩形框式的结构以减小接地电阻;对短路故障下和雷击故障下石墨基柔性接地装置在的温升情况进行了仿真计算,结果表明测试装置可在短路故障工况下正常运行,而在三十年一遇雷击故障下局部温升过高。研究结果对10kV城市配电网中石墨基柔性接地装置的设计、选型和应用具有重要参考价值。

    Abstract:

    In order to study the application of flexible graphite grounding material in power distribution systems, a finite element simulation model of flexible graphite grounding device is constructed, by which the grounding resistance of a group of 10kV power distribution system flexible graphite grounding devices is calculated. It is proposed that the rectangular frame structure should be preferentially used in urban distribution networks to reduce grounding resistance by combining with the inherent characteristics of flexible graphite grounding material and common resistance reduction methods. The temperature rise of the flexible graphite grounding device under short-circuit fault and lightning fault has been simulated and calculated. The test device can operate normally under short-circuit fault conditions, but the local temperature rise is over standard under the lightning fault that once in 30 years.The research results have important reference value for the design, selection and application of flexible graphite grounding devices in 10kV urban distribution networks.