Gas leak location algorithm for complex drawer structure
CSTR:
Author:
Affiliation:

1.National Key Laboratory of Electronic Measurement Technology, North University of China, Shanxi,Taiyuan 030051, China; 2. Key Laboratory of Instrumentation Science & Dynamic Testing of Ministry of Education,Shanxi, Taiyuan 030051, China

Clc Number:

TP312

  • Article
  • | |
  • Metrics
  • | |
  • Related [20]
  • | | |
  • Comments
    Abstract:

    Aiming at problems such as missing and false alarms that may be caused by the complex drawer structure due to its irregular structure, small area for installing sensor modules, and many monitoring nodes. This paper designs a concentration gradient algorithm that accurately locates the leakage point.Through the experimental test, it is proved that the whole monitoring system can work normally in the environment of - 15 ℃ to 55 ℃.The false alarm rate of the system is less than 3% and the missing alarm rate is less than 1%, which verifies the stability and practicability of the whole system.In other similar complex drawer structures with the risk of gas or liquid leakage, such as chemical industry, agriculture, medicine, military, environmental protection and other specific scenarios, this technology meets the needs of a wide range of universal testing.

    Reference
    Cited by
    Comments
    Comments
    分享到微博
    Submit
Get Citation
Share
Article Metrics
  • Abstract:55
  • PDF: 223
  • HTML: 0
  • Cited by: 0
History
  • Online: August 26,2024
Article QR Code